Universal I/O Module 8 outputs 8 inputs KNX ÆVO Series

DIN-Rail mount modules

CODE: EK-FG1-TP-I

Description

ÆVO built to last - Unbreakable reliability and resilience for a hassle-free tomorrowThe EK-FG1-TP-I universal I/O module from the ÆVO Series allows you to control up to 8 groups of electrical devices, such as lights and valves, or up to 4 motorized drives, such as blinds and 3-way valves, independently and in any combination you like. for this purpose, the device has outputs equipped with potential-free bistable relay contacts that guarantee that the set control status is maintained even in the event of a power failure.

In addition, EK-FG1-TP-I allows the control of up to 8 drives, scenarios, up to 4 motors, dimmers, or the climate control of up to 8 rooms using the integrated thermostat/hygrostat function, by reading traditional commands and sensors equipped with potential-free contacts or passive NTC temperature probes; For this purpose, the device has 8 analog/digital inputs that can be configured independently with interrogation voltage produced inside the device.

The product is equipped with buttons for manual control and LEDs for status indication; a button allows switching between automatic and manual operation. The device has an integrated KNX bus communication module and is designed for mounting on a 35 mm profile rail. Power is supplied via the KNX bus and no auxiliary power supply is required.

Technical data
Power supply 
  • 30 Vdc voltage via KNX bus
Outputs
  • Number: 8 (bistable relays)
  • Voltage 230V AC
  • Current: 16 A
Inputs
  • Number: 8 (configurable analog/digital)
  • For passive temperature sensors (NTC 10 kΩ at 25°C)
  • For switches, buttons, or traditional potential-free sensors
Supply

The supply includes a terminal for connection to the KNX bus line. Any NTC temperature sensors to be connected to the inputs must be ordered separately.

Functions / Features
  • Plastic casing

  • Buttons and LEDs for control and output status indication on the front panel

  • Button and LED for programming or manual/automatic operation on the front panel

  • Bus line connection via KNX terminal

  • Connection of loads to outputs via screw terminals with cable cross-section up to 4 mm2

  • Connection of loads to inputs via screw terminals with cable cross-section up to 2.5 mm2

  • Connection of different phases on adjacent outputs

  • Device with 4 modular units (1 MU = 18 mm)

Configurationa and commissioning
STEKFG1TPI_EN
  • v. 1.0 (03/11/2025)
  • PDF | 1,1 MB
  • Download
FISPEKFG1TPIIE01
  • v. 1.0 (26/09/2025)
  • PDF | 2,1 MB
  • Download
MAEKFG1FI1TPI_EN
  • v. 1.2 (08/05/2026)
  • PDF | 5 MB
  • Download
APEKFG1TPI01
  • v. 0.1 (02/12/2025)
  • KNXPROD | 1,4 MB
  • Download
CEEKFG1TPI
  • v. 1.0 (03/11/2025)
  • PDF | 883,4 KB
  • Download
UKCADCEKFG1TPI
  • v. 1.0 (03/11/2025)
  • PDF | 432 KB
  • Download
EK-FG1-TP-I_v.03.1.1_upgrade
  • v. 03.1.1 (11/06/2026)
  • ZIP | 7,8 MB
  • Download
DQEKFG1TPI
Questo sito o gli strumenti terzi da questo utilizzati si avvalgono di cookie necessari al funzionamento ed utili alle finalità illustrate nella cookie policy. Se vuoi saperne di piú o negare il consenso a tutti o ad alcuni cookie, consulta la sezione cookies. Chiudendo questo banner, scorrendo questa pagina, cliccando su un link o proseguendo la navigazione in altra maniera, acconsenti all'uso dei cookie.